FREQUENCY RESPONSE Frequency response will depend on signal amplitude, supply pressure, and internal design parameters. Amplitude ratio of frequency response is not allowed to exceed +2dB.
TRANSFER FUNCTION In system design, the transfer function of a double nozzle two stage flow control servo valve in series FF can be proximately estimated by:
The expression of series FF servo valves as follows
Example: 00521TP10 expresses rated flow of 5L/min, rated supply pressure of 21MPa, a general connector over pressure port, and rated current of 10mA. If customers have special have requirements for any other rated flow, rated current, coil resistance, or rated supply pressure, please consult with 609 in ordering. If customers have no special requirement either for the type of connector or for its location, please use a general connector T and location over control 2.